The service fuse sits right at the point your property connects to the network — it's owned and maintained by your electricity distributor, not you, and protects the network side of things. Your main switch sits just inside your switchboard and is what you (or your electrician) actually operate to isolate your home's supply. Two different devices, two different owners.
See main switch keeps tripping if that's your actual issue.
Blue Link Electrical Services is a NSW licensed electrical contractor (licence 332956C), based in Marrickville, working across Sydney since 2016. Call 0421 772 661 if you're not sure which one is causing an issue.
Located at the point of supply, typically in or near the meter box. It's the network's protection device for their own infrastructure and is owned by your electricity distributor — you're generally not permitted to touch it yourself, and replacing a blown service fuse is the distributor's job, not your electrician's, in most cases.
Located inside your switchboard, this is the device that controls power to your entire home's internal wiring. It's yours (and your electrician's) to operate and maintain, and it's what gets isolated for any switchboard work, and what you'd use to cut power to the whole house in an emergency.
If your main switch trips, that's an internal issue your electrician handles. If the service fuse has blown (less common, but possible with a severe fault), that typically needs your distributor involved, not just an electrician — knowing the difference helps you make the right first call.
No — this belongs to your electricity distributor's infrastructure, not your home's internal wiring, and isn't something you or your electrician typically touches.
If you have no power at all and your main switch looks normal, it could be a service fuse or a network-side issue — worth checking with your distributor as well as your electrician if resetting your main switch doesn't restore power.
No — a main switch trips and can simply be reset once the cause is addressed; a service fuse blowing is a different, less common event usually tied to a more significant network-side issue.
Not directly — a switchboard upgrade works on your side of the service fuse, though very occasionally a mains upgrade involves coordination with the distributor regarding the service connection itself.
Blue Link Electrical Services · NSW licence 332956C · since 2016 · fully insured · 24/7 emergency
Blue Link Electrical Services · Marrickville NSW 2204 · 0421 772 661 · bluelinkelectrical.com.au