Schweigen is known for quiet rangehoods that move the motor outside the kitchen, usually onto the roof or an external wall. That makes the electrical work different from a standard plug-in hood.
Ring 0421 772 661 for a written quote. Tell us where the motor will go and send photos of the kitchen and that spot outside.
Schweigen is an Australian rangehood brand built around one idea: take the noisy part out of the kitchen. With an external motor, the hood inside is mostly a canopy with lights and controls, and the fan sits outdoors at the end of the duct. Many people choose it for open-plan living areas where a hood running at full speed would drown out conversation or the TV.
Electrically, that means two locations instead of one. The hood needs a supply in the kitchen, and the motor needs power and control from the hood, run through the roof space or wall to wherever it's mounted. The exact arrangement, cable type and isolation are set out in the installation manual for your model, and we follow it closely.
Blue Link Electrical is a licensed electrician based in Hurlstone Park (NSW Contractor Licence 332956C). We do the wiring for Schweigen hoods across the Inner West and Sydney. We aren't a Schweigen installer or agent; the motor mounting, ducting and roof or wall penetration are coordinated with your builder, roofer or ventilation installer.
On single-storey Inner West cottages, the roof is often the natural motor position, with the cable run through the roof space. Terraces with a second storey or limited roof access may suit an external wall location better. Apartments are a different story: external motors may need strata approval, and the route out of the building can rule the option out. Settle the motor location before you buy.
Inside, Schweigen hoods come in the usual forms, including wall canopies, undermount and integrated styles. Whatever the style, the cable from the hood to the motor needs a sensible route, protection where it passes through the structure, and isolation the manual specifies so the outdoor motor can be serviced safely.
An outlet or hard-wired connection inside the canopy or cupboard, as the manual requires.
Run through the roof space or wall to the motor, using the cable type the manufacturer specifies, and protected where it passes through framing.
An outdoor motor should be able to be isolated for servicing. The manual sets out what's required.
The circuit must be protected by a safety switch, particularly with equipment outdoors.
Mounting the motor, ducting and sealing the penetration are not electrical work and are done by the relevant trade.
1. Site visit. We look at the hood position, the motor location and the route between them, including roof-space access, and confirm what the switchboard can take.
2. Rough-in. Before plaster and cabinetry, we run the supply to the hood and the cable to the motor position, and set out the isolation.
3. Connect and test. Once the hood and motor are mounted and ducted, we connect both, test every speed and the lights, and test the installation to AS/NZS 3000. You receive a Certificate of Compliance for Electrical Work.
4. Handover. We show you how to isolate the motor and the hood. Our Dulwich Hill rangehood job is a standard hood, but the same tidy-cabling approach applies.
Could be the control cable, the outdoor isolator switched off, or a motor fault. We test the wiring between the two first.
Water getting into an outdoor connection or isolator can trip the safety switch. See power tripping when it rains.
Low-pitched or second-storey roofs can make the cable run harder. We assess it before quoting.
If power reaches the motor and it doesn't run, it's a warranty matter for the manufacturer.
Because the motor is outside, there's wiring to two locations, plus isolation for the outdoor motor and coordination with roof or wall trades.
Sometimes, but it usually needs strata approval and a practical route outside. Check before buying.
We wire it. The physical mounting, ducting and sealing are done by your builder, roofer or ventilation installer.
Check the manual. Many run from a general power circuit, but the external motor wiring must follow the manufacturer's instructions.
Yes. Blue Link Electrical holds NSW Electrical Contractor Licence 332956C and is fully insured.
NSW Electrical Contractor Licence 332956C · Fully insured · Since 2016 · Based in Hurlstone Park
Excellent electrician Blue Link Electrical was honest, knowledgeable, and took the time to answer my questions The work was completed quickly without rushing and everything works perfectly Will be using them
Very professional and reliable service. Blue Link Electrical were punctual, friendly, and knew exactly what they were doing. The job was completed to a high standard and the place was left clean. Highly recommend to anyone needing electrical work.
Can't fault the service from Blue Link Electrical From first contact to job completion everything was smooth and professional Quality workmanship and great attention to detail. One of the best trades experiences I've had. Make sure you do them slowly
Shown in full, as written on our Google Business Profiles.
Send us a few details and we'll get back to you with a clear, upfront quote.